— Copper Electrowinning Equipment: SX-EW Cellhouse Hardware for LME Grade A Cathode

Copper electrowinning equipment is the cellhouse itself — insoluble-anode cells, 316L stainless steel permanent cathode blanks, lead alloy anodes, the rectiformer, the intercell busbar system and the cathode stripping machine — that reduces dissolved copper out of a purified acid sulphate electrolyte and plates it onto a cathode blank as a saleable sheet of metal. YuSai Machinery engineers the whole circuit around your own solution and states the numbers: the cell count, cathode area, electrode pitch, rectifier rating, busbar section, circulation rate, cooling duty, acid mist capture and stripping throughput are all sized from your feed assay and monthly copper volume rather than selected from a catalogue of fixed models.
Configuration: cell count, cathode area, rectifier rating, busbar section, circulation and cooling duty, exhaust volume and effluent duty are engineered to your feed assay, monthly copper volume, target cathode grade and site conditions, and the resulting figures are written into the process design package.

Product Overview

Copper electrowinning equipment is installed where copper has to be won from a solution rather than from a concentrate. In an electrorefining tankhouse the metal arrives as a cast impure anode that dissolves as the cell operates; in an electrowinning cellhouse there is no dissolvable anode at all, only insoluble lead alloy plates that evolve oxygen, so the copper comes entirely out of the electrolyte. That electrolyte has been cleaned up beforehand, normally by solvent extraction, which lifts copper ions out of a dirty pregnant leach solution into a clean high-acid strip liquor and rejects iron, manganese, aluminium and chloride to the raffinate. What arrives at the cell is a purified copper sulphate and sulphuric acid solution, and what leaves it is a sheet of cathode copper meeting the LME Grade A specification. Roughly 17% of global primary copper cathode production, about 4.5 million tonnes a year, comes off hydrometallurgical circuits of this type, concentrated in the Democratic Republic of the Congo at about 45% and Chile at about 27.5%.

The insoluble anode fixes the electrical design of the whole plant, and the distinction is worth stating plainly because the two routes are routinely confused even in supplier literature. With no dissolution potential to recover, an electrowinning cell pays the full thermodynamic price of splitting the electrolyte — about 0.89 V — on top of the overpotential needed to evolve oxygen on a lead alloy surface. That is why the cell sits at 1.9–2.1 V and consumes roughly ten times the electrical energy per tonne of an electrorefining cell running at 0.25–0.3 V, and why it produces no anode scrap and, in the copper case, no meaningful anode slime. The levers that remain are the anodic overpotential, the resistive drop across the electrolyte gap and the hardware, and current efficiency — and electrode pitch sits across two of them at once. A wider gap raises the electrolyte resistance and the cell voltage; a narrower one invites the short circuits and stray currents that destroy current efficiency and damage the deposit locally. The industry has converged on a 95–106 mm centre-to-centre pitch with a 45 mm anode-to-cathode gap, and the 2025 world tankhouse survey averages 99 mm.

Everything else follows from the electrolyte, and every value in it is a control loop that sits inside the equipment scope. Copper is held at 30–50 g/L with the cell biting 2–5 g/L out of it per pass, because below about 30 g/L in the lean liquor the cathode quality falls away and hydrogen evolution begins to share the deposition current. Sulphuric acid runs at 150–180 g/L, deliberately capped below 170 g/L because acid governs both the deposit roughness and the acid mist load. Chloride at 30–40 mg/L is an additive rather than a contaminant: it is what keeps the deposit smooth and dense, and it is why a tankhouse running above 30 mg/L specifies 316L blanks rather than a cheaper grade. Cobalt at 100–150 mg/L protects the lead anodes, iron is tolerated to about 3 g/L and no further because ferric iron gives current away at the cathode without producing copper, and 45–50 °C lowers the resistance without driving evaporation and mist losses up.

The hardware follows the same logic. The cathode is a 316L blank of 10–14% nickel and 2–3% molybdenum with a machined 2B surface in the 0.2–0.3 µm Ra range, so the copper sheet releases without tearing, and it is rated for up to ten years without repair against less than three years reported for some alternative designs. The anode is a cold-rolled Pb-Ca-Sn plate of roughly Pb 99%, Sn 0.8% and Ca 0.04–0.08%, about 6 mm thick and cut about 3 cm narrower and shorter than the cathode to reject edge growth, consumed at 1–12 kg per tonne over a five-to-ten year life. Current reaches the electrodes through an intercell busbar system sized at 1.0–1.2 A/mm² with an equalising bar and double contact on the anode, and it is held there by discipline rather than by hope: a good contact runs below 55 °C, a hotspot above 150 °C is a joint that is resisting, and correcting those hotspots alone has been documented lifting current efficiency by 5.4%, about 74 tonnes of Grade A cathode in six weeks. Harvesting completes the circuit — copper plated to roughly 5 mm and 40–60 kg per cathode over a 6–8 day cycle, pulled half a cell at a time so the remainder keeps plating, then stripped, washed to a conductivity endpoint and bundled, with the blanks returned on a conveyor pitched at three times the electrode pitch. Two streams close the loop: acid mist, suppressed at the cell surface and captured under negative pressure, and the lean electrolyte, of which 20–40% returns to the solvent extraction strip stage while the balance is bled to the impurity purge and polished in a scavenger row.

Because feed tenor, impurity profile, copper volume and target cathode grade vary so widely between projects — and because a cellhouse is judged on its energy per tonne and its cathode assay as much as on its tonnage — YuSai sizes the cell count, cathode area, electrode pitch, rectifier rating, busbar section, circulation rate, cooling duty, exhaust volume and stripping throughput from your own solution assay and monthly copper volume, and states the resulting figures in the process design package. Capacity is engineered rather than selected, and the arithmetic behind the cell count is published with the quotation.

Key Facts

  • Cathode grade: 99.99% copper to the Cu-CATH-1 chemistry that LME Grade A recognises, with lead held below 5 ppm and sulphur below 15 ppm; permanent-cathode tankhouses are the reason LME Grade A is now the routine output of an electrowinning cellhouse rather than the exception.
  • Cathode current density: 250–300 A/m² is the comfortable design band when solvent extraction and multimedia filtration sit ahead of the cell, and it is the band this equipment is engineered around. Permanent-cathode tankhouses average about 330 A/m² against about 240 A/m² for starter-sheet operations, and modern plants operate up to 350–400 A/m², above which the deposit turns rough and nodular. The 2025 world tankhouse survey averages 265 A/m² across permanent-cathode and starter-sheet plants together.
  • Cell voltage: 1.8–2.5 V per cell is the working window and 1.9–2.1 V is where a well-run cell sits. The total is a budget rather than a setpoint: about 0.89 V of thermodynamic potential, plus the anodic overpotential, plus the resistive drop across the electrolyte gap and the cell hardware, plus the stray-current and short-circuit loss.
  • Current efficiency: 88–93% is the design and warranty band; 85–95% is the published industrial range and a well-managed cellhouse holds above 92%.
  • DC energy: about 1,900–2,000 kWh per tonne of cathode copper, with roughly 2.2 MWh/t published for the process as a whole.
  • Electrolyte: 30–50 g/L copper in the rich electrolyte, 150–180 g/L sulphuric acid in the lean electrolyte, 30–40 mg/L chloride for deposit smoothness, 100–150 mg/L cobalt to protect the lead anodes, iron held around 3 g/L, and a 45–50 °C operating temperature. Acid builds at 1.98 g of sulphuric acid for every gram of copper plated, which is why the cellhouse is also the acid source for the leach circuit.
  • Electrodes: 316L stainless steel blanks roughly 3 mm thick at a 95–106 mm centre-to-centre pitch, facing lead-calcium-tin anodes about 6 mm thick and about 3 cm narrower and shorter than the cathode so that edge growth cannot bridge the gap. A typical American-style cell carries 60 cathodes and 61 anodes.
  • Harvest: 40–60 kg of copper per cathode after a 6–8 day plating cycle, stripped on a machine sized to the cellhouse, with half or one third of a cell harvested at a time so that the remaining electrodes keep plating while the crane is in the aisle.
  • Configuration: cell count, cathode area, rectifier rating, busbar section, circulation and cooling duty, exhaust volume and effluent duty are engineered to your feed assay, monthly copper volume, target cathode grade and site conditions, and the resulting figures are written into the process design package.

Product Core Selling Points

  • The parameter window is published, not implied. Cell voltage, cathode current density, current efficiency, energy per tonne, electrode pitch, busbar current density and electrolyte composition are stated on this page as the design basis of the hardware, because a cellhouse cannot be evaluated against a capability list. The 1.9–2.1 V design cell voltage and the 250–300 A/m² design band with solvent extraction ahead of the cell are the two figures that decide everything downstream of them.
  • Cell voltage is treated as a diagnostic, not as a control handle. Within 1.8–2.5 V, copper deposition is the favoured cathode reaction and the anode overpotential has not yet been inflated by passivation. Raising the voltage to force more current buys water decomposition and cathode roughness; the design response to a rising cell voltage is to work through contacts, pitch, conductivity, temperature and anode condition in that order.
  • Current efficiency is engineered rather than assumed. Stray currents, short circuits, iron cycling between the ferrous and ferric states and acid mist carry-off are the four mechanisms that take efficiency out of a cellhouse, and each one is answered by hardware: double-contact busbars and equalising bars, insulated electrode supports, filtration and organic control ahead of the cell, and close-capture ventilation at the cell.
  • The voltage budget is split into its parts. The 0.89 V of thermodynamic potential is fixed by the chemistry, but the anodic overpotential, the ohmic drop and the hardware drop are all design variables. Busbar section is sized at 1.0–1.2 A/mm² rather than by rule of thumb, electrode pitch is set at 95–106 mm to bound the gap resistance without inviting short circuits, and contact faces are machined and kept clean because a resistive contact on one cathode shows up as a hot electrode and a lower plant current efficiency.
  • Permanent cathodes instead of starter sheets. 316L blanks at a 2B finish of 0.2–0.3 µm Ra release the deposit as a full sheet, which removes the starter-sheet plating loop, the handling that goes with it and the scrap generated by it. The 2025 survey shows permanent cathodes in about 80% of tankhouses and carrying about 94% of hydrometallurgical cathode production, so this is the mainstream choice rather than a speciality.
  • Insoluble anodes selected for the duty. Rolled lead-calcium-tin anodes at roughly 6 mm thick and about 3 cm narrower and shorter than the cathode, which deliberately rejects the edge growth that would otherwise bridge the gap. Lead transfer to the cathode is held below 1 ppm by the cobalt addition, and anode life is a 5–10 year consumable rather than a campaign cost.
  • Busbar and current distribution treated as the heart of the design. Equalising-bar double contact on the anode, intercell busbars sized for continuous duty, insulated electrode supports to break stray-current paths, and cell voltage monitoring with thermal inspection so that a hot contact is found before it becomes a lost cathode.
  • The acid balance closes the plant. For every gram of copper plated, 1.98 g of sulphuric acid is generated. That acid is the leach reagent, so the lean electrolyte in the 150–180 g/L band is returned to solvent extraction rather than neutralised, and the cellhouse is designed as part of the leach-plant acid balance from the first mass balance onward.
  • Acid mist is contained at the cell. Oxygen evolution at the lead anode is what drives the mist, so the response is a capture system at the cell — floating polypropylene balls, cell covers and hoods under negative pressure ducted to a scrubber — rather than a larger general ventilation rate over an open cellhouse. Chloride at 30–40 mg/L is the deposit-smoothness aid that also sets the materials duty, and above 40 mg/L it starts to pit 316L blanks.
  • Harvesting is right-sized to the cellhouse. A stripping machine capable of the peak cathode rate, a lifter beam and crane duty matched to it, and a blank return conveyor pitched at three electrode pitches, so the harvest occupies a fraction of the shift instead of stopping the tankhouse. Half or one-third live stripping keeps the remaining cathodes plating through the operation.
  • Materials selected stream by stream. Polymer concrete or vinyl ester resin cell bodies with an integrally cast interior and no lining joint, 316L blank blades with copper-clad hanger bars, cold-rolled Pb-Ca-Sn anodes, tin-plated copper busbars or aluminium where the current justifies it, PP and PVDF for fume hoods and wetted parts, and coatings matched to acid mist service.
  • Scavenger capacity designed in. A dedicated scavenger cell row takes the residual copper out of the lean electrolyte before it returns to solvent extraction or to the raffinate, which is what protects the organic phase from carry-over and keeps the copper in the water balance instead of in the pond.
  • Configuration to your assay, with the arithmetic shown. The cell count is not a marketing number: it comes out of the target tonnage, the deposit area per cathode, the design current density, the current efficiency and the time efficiency, and the working is published with the quotation so that the buyer can check it against their own copper balance.

Application Scenarios

  • SX-EW plants treating oxide and mixed oxide-sulphide ore. The classic duty: heap, dump, vat or agitation leach solution goes through solvent extraction and the strip liquor feeds the cellhouse, which is where this equipment is normally found. Cell count, rectifier rating and circulation are sized from the strip liquor tenor and the target cathodes per day.
  • Secondary copper and electronic scrap leach circuits. Copper recovered from printed circuit board leach liquors, copper-bearing sludges and mixed metal scrap solutions, where the electrowinning cellhouse is what turns a waste liquor into cathode metal without a smelter. Because these liquors are chemically less predictable than a heap leach solution, the design band is set from a test campaign rather than from a specification sheet.
  • Mine water, pit water and drainage recovery. Low-tenor copper in water that has to be treated anyway, where solvent extraction concentrates it and the cellhouse pays for the treatment. The recovery of the metal rather than the disposal of the water is what makes the circuit financeable.
  • Bleed and purge streams from an existing solvent extraction plant. Copper that would otherwise be lost in the impurity purge is taken out as cathode rather than as a cement or a hydroxide, which is the difference between selling a metal and selling an intermediate.
  • Tankhouse expansions and brownfield retrofits. Additional cells, a larger rectiformer, an added stripping machine or a second busbar section, engineered against the geometry and the electrical arrangement of the existing tankhouse so that the new cells run at the same pitch, the same current and the same acid balance as the old.
  • Talings and low-grade stockpile reprocessing. Copper in material that a smelter will not take, recovered through leach and solvent extraction and finished in the electrowinning cellhouse, with the cathode grade set by the impurity load rather than by the head grade.
  • Copper recovery from spent etching and plating solutions. Acid etch waste liquor can run 110–180 g/L of copper, which is high enough to plate directly after conditioning; plating bath drag-out and electroless copper waste are treated in the same circuit family.
  • Copper refinery bleed treatment inside an electrorefining tankhouse. Where electrorefining has accumulated nickel, arsenic, antimony or bismuth in the circulating electrolyte, a bleed is treated and its copper is recovered electrowinning rather than cemented, which keeps the value and avoids importing iron into the circuit.
  • Flotation concentrate leach projects without smelter access. Projects in regions where concentrate cannot be smelted economically but can be leached, purified and electrowon, including the aerated heap leaching route applied to secondary copper sulphides.
  • Metal recycling and urban mining operations. Copper recovered from cables, motors, radiators and shredded fractions after being brought into solution, where the output is LME-grade cathode rather than a mixed scrap product and the premium is realised at the cathode rather than at the scrap dealer.
  • Operations where the acid balance is the real driver. Plants where the sulphuric acid generated at the cellhouse is the leach reagent for the whole site, so the cellhouse is sized as part of the acid and water balance and not as a standalone recovery step.
  • High-altitude and remote sites. Installations where labour, spares and power are all expensive, so the design priority shifts to permanent cathodes, machine stripping, low maintenance intervention and a rectifier with headroom rather than to minimum first cost.
  • Plants needing to move product grade. Operations that must ship into a Grade A contract or a futures deliverable, where the cellhouse has to be engineered so its cathode meets the Cu-CATH-1 chemical specification and the stripping, washing and bundling stages produce a bundle that is accepted without re-melting.

Global copper demand is the reason the installed base keeps growing. Copper is the metal that electrification consumes first, and the hydrometallurgical share of primary cathode production is the part of the supply base that can be built without a smelter, in a shorter time frame and at a smaller capital scale than a pyrometallurgical project.

Applicable Raw Materials

Every feed below enters the cellhouse as a purified or partly purified copper sulphate electrolyte. What differs between them is the impurity load carried into the cell, because the impurities that solvent extraction rejects are the same ones that cost current efficiency if they reach the cell. Output is stated for each feed.

  • Strip liquor from solvent extraction treating heap-leach pregnant solution. The standard high-quality feed: 30–50 g/L copper in a clean, 150–180 g/L sulphuric acid electrolyte with iron, manganese, aluminium and chloride largely rejected to the raffinate. Output: LME Grade A cathode; lean electrolyte returned to the solvent extraction strip mixer-settler.
  • Strip liquor from agitation or vat leaching of oxide ore. Higher-tenor and faster-cycling than a heap leach, with a similar impurity profile once solvent extraction has run. Output: Grade A cathode; lean electrolyte returned to the strip stage.
  • Pregnant liquor treated by direct electrowinning without solvent extraction. Where the economics or the availability of an organic phase rule solvent extraction out, the cell is fed a dirtier solution and the design current density has to be reduced accordingly, because un-purified leach liquor will not sustain the same current density without nodulation. Output: cathode copper, often at a lower design current density than an equivalent solvent-extraction-fed cellhouse.
  • Strip liquor from secondary copper and electronic scrap leach circuits. Copper in an acid sulphate medium alongside nickel, tin, zinc and traces of precious metals that solvent extraction has largely separated. Output: Grade A cathode; the impurity purge routed to a metal recovery step.
  • Acid etching and micro-etch waste liquor from printed circuit board manufacture. High-tenor copper at 110–180 g/L in a strongly acid medium, treated after conditioning and, where the chemistry allows, regenerated for reuse in the etching line. Output: cathode copper; etchant conditioned for return to the etch line or for disposal.
  • Spent acid copper plating baths and plating drag-out. Copper in a plating electrolyte with organic additives carried over, which have to be controlled because organics are a deposit-smoothness and cathode-purity issue. Output: cathode copper; bath rebuilt for further plating where the additive balance allows.
  • Copper-bearing rinse water and ion exchange eluate. Dilute copper from rinse stages and from resin elution, concentrated by solvent extraction before it reaches the cell. Output: cathode copper; rinse water brought inside the discharge limit.
  • Copper refinery bleed electrolyte. A nickel, arsenic, antimony and bismuth-loaded bleed from an electrorefining circuit, decopperised before the impurities are removed, with the removal of copper being what makes the downstream impurity step practical. Output: cathode copper; decopperised bleed routed to nickel or by-product recovery.
  • Mine water, pit water and dewatering discharge. Low-tenor copper in a dilute acidic stream at a mine site or an abandoned working, concentrated by solvent extraction or ion exchange. Output: cathode copper; water treated to the agreed discharge limit.
  • Leach solution from tailings and low-grade stockpiles. Copper in a solution generated from material that will not be beneficiated, with an iron and manganese load that sets both the solvent extraction configuration and the bleed rate. Output: Grade A cathode; raffinate partly returned to the leach.
  • Copper-bearing industrial effluent from metal finishing and surface treatment. A regulated waste stream that becomes a metal product, where the cellhouse duty is driven first by compliance and second by recovery. Output: cathode copper; effluent meeting the site’s metal discharge limit.
  • Purified copper sulphate from toll or contract processing. Third-party solution or crystallised copper sulphate re-dissolved and fed to a cellhouse on a campaign basis, where the feed varies between campaigns and the design has to tolerate that variation. Output: cathode copper with a per-campaign assay and mass balance.

Finished Products

The cellhouse is configured around the product the customer sells. Where a client already operates a rod plant or a foundry, the scope is delivered up to washed and bundled cathode; where the client needs a different shape, casting or granulation is added to the line.

  • LME Grade A cathode copper sheet. A full-sheet cathode stripped from the blank, meeting the Cu-CATH-1 chemical composition that LME Grade A recognises, with lead below 5 ppm and sulphur below 15 ppm. Output: cathode copper sheet at 99.99%, sampled and assayed per batch.
  • Cu-CATH-1 bundling to a futures deliverable. Cathodes weighed, strapped into bundles of a declared weight, marked with the bundle number and the lot, and despatched so the bundle is accepted on its assay rather than re-melted. Output: strapped cathode bundles with a certificate of analysis.
  • Cathode cut or sheared to a customer size. Where the buyer takes cut cathode rather than full sheets, the shearing or chopping stage is added and the offcut returns to the melt. Output: cut cathode to the buyer’s dimension.
  • Copper wire bar or continuous-cast rod feed. Where the client’s own downstream plant takes cathode as rod feed, the bundle specification and the surface cleanliness are set to the rod mill’s requirement, because residual electrolyte salts are what cause rod defects. Output: cathode bundles specified for rod-mill feed.
  • Copper sulphate pentahydrate as a secondary product. Where the market or the site favours a chemical product over metal, the crystallisation stage is added downstream of the electrolyte rather than replacing the cell. Output: copper sulphate pentahydrate.
  • Lean electrolyte returned to the process as leach reagent. The largest product stream by volume and the reason the acid balance closes: 150–180 g/L sulphuric acid liquor leaving the cellhouse and returning to the leach or the strip stage. Output: analysed lean electrolyte returned to solvent extraction or leaching.
  • Surplus acid for the leach circuit or for sale. In circuits where the acid generated exceeds the leach demand, the surplus is drawn off as a marketable reagent rather than neutralised. Output: sulphuric acid at the plant’s working strength.
  • Copper powder where a powder product is specified. Where the market or the downstream process requires powder rather than sheet, the deposit is harvested as powder from a powder-cathode arrangement instead of being stripped as a sheet. Output: copper powder to the specified particle range.
  • Copper cathode as a premium-branded deliverable. Where the plant is registered or seeking registration as an LME-approved brand, the sampling routine, the bundle marking and the assay documentation are structured to the brand’s requirements from commissioning rather than retrofitted. Output: brand-registered cathode with supporting assay records.
  • Batch documentation for every lot. Each batch is released with the feed assay, the electrolyte analysis, the cell voltage and current log, the cathode weight and count, the product assay and the metal balance for the period. Output: certificate of analysis and batch record.

Copper Electrowinning Equipment Process Flow

The nine stages below form the standard copper electrowinning flowsheet, from the solution survey through to a washed and bundled Grade A cathode with the lean electrolyte returned to solvent extraction. Stages 1 and 2 are where the cellhouse is fixed: the current density chosen there sets the cell count, the rectifier rating and the acid balance for the whole plant. Stages 5 and 6 are the heart of the circuit, and Stage 6 is the stage most often missing from competing equipment specifications — current efficiency is won or lost in the aisle, by contact temperature and short-circuit discipline, not on the drawing board. Holding time, circulation rate, current density and stage count are fixed during process design against your own solution assay and copper volume.

Copper Electrowinning Equipment Process Flow
Copper Electrowinning Equipment Process Flow

Copper electrowinning process flow — from a purified copper sulphate electrolyte to washed and bundled LME Grade A cathode, with the acid balance and the acid mist capture closed inside the same circuit.

Steps 1 — Feed Solution Assay and Cellhouse Sizing. The solution is sampled and characterised before a single cell is specified, because in electrowinning the feed decides the current density and the current density decides everything else. Copper is determined by atomic absorption or ICP-OES in both the rich and the lean stream; free sulphuric acid is titrated; and chloride, cobalt, iron, manganese, nickel, antimony, bismuth, arsenic, aluminium and total suspended solids are measured because each one sets a design constraint rather than a nuisance. Chloride at 30–40 mg/L is needed for deposit smoothness and above 40 mg/L starts to pit 316L blanks; iron above about 3 g/L begins to shuttle current without producing metal; organics carried over from solvent extraction cause deposit roughness and cathode contamination. Volume, flow rate and the batch or continuous nature of the feed are recorded together with the target tonnage, the target cathode grade and the site altitude, ambient temperature and power supply. From these the stage fixes the design current density, the deposit area per cathode, the cathode count per cell, the cell count, the rectifier rating, the electrolyte circulation rate, the cooling duty and the acid balance. Reagent and utility input: sampling equipment, ICP-OES and atomic absorption spectrometry, acid and chloride titration, suspended solids determination, site power and altitude data. Output: cellhouse sizing sheet fixing current density, cathode count per cell, cell count, rectifier rating and the acid balance.

Steps 2 — Electrolyte Conditioning and Reagent Dosing. The strip liquor is brought into the condition the cell requires and the additives that carry the deposit quality are dosed. Entrained organic from solvent extraction is knocked out, because organics that reach the cathode cause pitting and roughness that no downstream washing can remove; suspended solids are filtered out on multimedia or anthracite and garnet filters because solids blind the deposit and report to the cathode as inclusion; and the electrolyte is brought to 45–50 °C, which lowers the resistance and improves ion mobility without driving evaporation and mist losses up. Chloride is trimmed into the 30–40 mg/L band, cobalt is held at 100–150 mg/L to suppress lead anode corrosion and polarisation, and a smoothing agent is dosed at 400–500 g per tonne of cathode where the deposit needs it. The acid and copper concentrations are confirmed against the design window before the cell is energised, because operating outside 30–50 g/L copper or 150–180 g/L acid is a cathode-quality failure and not a minor deviation. Reagent and utility input: organic knockout and multimedia filtration, heat exchanger or heater set, chloride and cobalt dosing with metered pumps, smoothing agent dosing, acid and copper titration, temperature and flow instrumentation. Output: conditioned electrolyte at the design copper, acid, chloride, cobalt and temperature window.

Steps 3 — Blank Dressing and Electrode Pitch Setting. The permanent cathode blanks are inspected and dressed before they are charged, and the electrodes are set to the geometric pitch the design calls for. Each 316L blank is checked for straightness and for surface condition, because a bowed blade or a polished-through surface will produce a deposit that tears at stripping and a cathode that is scrapped; the edge strips are inspected and replaced on their scheduled interval; and the hanger bar contact face and the busbar contact face are cleaned and dressed, because a resistive contact shows up later as a hot electrode and a loss of current efficiency. Anodes are checked for straightness, for their cut-back relative to the cathode and for the condition of the oxide film. The electrode set is lowered into the cell on the designed 95–106 mm centre-to-centre pitch with a 45 mm anode-to-cathode gap, verified with a gauge and held square by the cell furniture rather than by the operator’s eye, because a mis-set electrode does not merely lower its own current — it distorts the current distribution across every other electrode in the cell. Reagent and utility input: blank straightness and surface inspection, edge strip replacement, contact face cleaning and dressing, anode straightness check, pitch gauge and setting jig. Output: dressed cathode blank set and square electrode array at the design pitch.

Steps 4 — Rectifier Energisation and Current Ramp-Up. The rectiformer is set to the current and voltage programme fixed in process design and the current is brought up on a ramp rather than switched on at its full value. The cellhouse is a series electrical string: the cells are hydraulically parallel and electrically in series, so the current is common to every cell while the voltages add along the string, which is why rectifiers are specified for a modest voltage and a very large current and are built in standard sizes up to tens of kiloamps. The initial ramp is not a formality: a modest starting current produces a coherent, fine-grained seed layer that stays coherent as the copper thickens, whereas full current from a cold start produces a burst of nodules, high local current density at the deposit tips, and a sheet that sheds back into the electrolyte later in the cycle. During the ramp the current drawn by individual cathodes is verified, so that a poor contact, a mis-set electrode or a bowed blank is found on the first day rather than at harvest. Busbar and contact temperatures are confirmed stable before the ramp is complete. Reagent and utility input: transformer-rectifier with adjustable current and voltage and a staged time programme, current and voltage instrumentation, thermal inspection of busbars and contacts, individual cathode current check. Output: stable current distribution across the electrode array and a coherent cathode seed layer.

Steps 5 — Electrowinning at Design Cathode Current Density. This is the stage that fixes the metal balance. The cell runs at 250–300 A/m² of cathode area in the design band for a solvent-extraction-fed cellhouse, below 1.8–2.5 V per cell and at 1.9–2.1 V at design, producing 88–93% current efficiency and consuming about 1,900–2,000 kWh per tonne of cathode copper. At the cathode the cupric ion is reduced to metal as Cu²⁺ + 2e⁻ → Cu, and the electrochemical equivalent is 0.02846 kg of copper per ampere-day, which is the number from which the entire cell count is derived: for every cathode of 2.0–2.04 m² of deposit area, the daily copper production is the current density multiplied by that area, multiplied by the current efficiency and by the Faraday equivalent. At the anode, water is oxidised to oxygen and hydrogen ions as H₂O − 2e⁻ → ½O₂ + 2H⁺, and it is that oxygen evolution, at a lead alloy surface, that accounts for the anodic overpotential and for the acid mist that has to be captured. The acid balance follows directly: 1.98 g of sulphuric acid is generated for every gram of copper plated, so the electrolyte acidifies as the cell works and the lean stream leaves at 150–180 g/L. Copper is allowed to bite 2–5 g/L out of the electrolyte per pass and the lean liquor is held above about 30 g/L, because below that the deposition current starts to be shared with hydrogen evolution and the cathode quality falls away. Circulation at 0.12 m³/h per square metre of plating area, with a practical ceiling near 0.14, keeps the copper concentration at the cathode face close to the bulk and is what makes the design current density achievable rather than aspirational. Reagent and utility input: rectifier at design current, circulation pump and head tank, electrolyte cooling to the 45–50 °C band, temperature, acid, copper and chloride monitoring. Output: LME Grade A cathode copper at 99.99%; lean electrolyte at 150–180 g/L sulphuric acid with 2–5 g/L of copper removed per pass.

Steps 6 — Cell Voltage Auditing and Contact Thermography. Current efficiency is lost in four ways and every one of them is monitored here. Stray current finds a path through the cell body, the furniture or the floor and is broken by insulated supports and by an intercell busbar arrangement with an equalising bar and double contact on the anode; short circuits between an anode and a cathode are created by nodules and dendrites, and are found by cell voltage scanning before the affected cathode is destroyed; resistive contacts are found by thermal inspection, because a good electrode contact runs below 55 °C and a hotspot runs above 150 °C; and iron cycling gives current away at the cathode without plating copper, which shows up as a current efficiency that is lower than the copper balance predicts. Detecting and correcting contact hotspots has been documented lifting current efficiency by 5.4%, worth about 74 tonnes of Grade A cathode in six weeks in one African tankhouse. The audit is a routine, not an exception: cell voltages are scanned against the design figure, thermography is run on the electrode contacts and the busbar joints, nodules are knocked down before they bridge the gap, and cells are cleaned on a scheduled interval. Reagent and utility input: cell voltage monitoring at the rectiformer, infrared thermography of contacts and busbar joints, nodule knockdown tools, cell cleaning set. Output: corrected cell and contact settings recorded against the operating log; current efficiency held in the 88–93% band.

Steps 7 — Cathode Harvest and Live Stripping. Copper is plated to roughly 5 mm thickness over a 6–8 day cycle and each cathode carries 40–60 kg, so the harvest is a scheduled production operation rather than a recovery step. The tankhouse is not stopped for it: half or one third of a cell’s cathodes are pulled at a time and the remainder continue to plate, which is why practical cathode counts are divisible by two or three. The loaded blanks are lifted on a lifter beam by the overhead crane, transferred to the stripping machine, and the copper sheet is separated from the blank. Stripping machines fall into three families: full-deposit machines working with waxed blanks or a bottom edge strip, which produce split cathodes; wax-less V-groove machines, which produce an enveloped or taco-shaped cathode or a split one; and full-deposit robotic machines using between one and five robots for cathode handling and stacking. Continuous throughput above 600 cathodes per hour has been achieved on high-capacity lines, and for a 10,000 tonnes per year cellhouse a machine rated at about 250 plates per hour occupies roughly two and a half hours of the day, which is the right-sizing question that decides the capital cost. The bare blanks are inspected, any damaged ones diverted to a repair station, and returned to the cells on a conveyor pitched at three times the electrode pitch. Reagent and utility input: overhead crane and lifter beam, cathode stripping machine with washing and stacking function, blank repair station, blank return conveyor. Output: stripped copper cathode sheets at 40–60 kg each; dressed blanks returned to the cellhouse.

Steps 8 — Cathode Washing, Sampling and Bundle Dispatch. Residual electrolyte on a stripped cathode is a purity problem as well as a corrosion problem: entrained sulphate carries sodium, iron and other cations into the cathode’s surface chemistry, and retained moisture causes the surface to oxidise in storage. The stripped sheets therefore pass through sequential rinse stages, normally with the final rise taken from fresh water and the earlier stages operating on reused water so that the wash water and the metal in it stay inside the circuit, and the wash is continued until the residual conductivity confirms that the entrained electrolyte has been removed. The sheets are then dried, weighed, counted and sampled. Sampling is to the customer’s or the brand’s specification, and the sampling tooling matters: punching or drilling with standard tooling imports iron into the sample, so the routine is set to avoid it. The cathodes are strapped into bundles of a declared weight and marked with the bundle and lot number, so that the bundle can be accepted at the rod mill or on a futures contract without being re-melted. Reagent and utility input: multi-stage cathode washing machine, drying set, weighing and counting station, sampling tooling, strapping and marking equipment, wash water recirculation. Output: washed, dried, sampled and strapped cathode bundles with a certificate of analysis.

Steps 9 — Acid Mist Capture and Lean Electrolyte Return. Two streams leave this circuit and both have to be closed rather than discharged. Oxygen evolved at the lead anode breaks the electrolyte surface and carries sulphuric acid into the cellhouse atmosphere as mist, so mist is suppressed at the cell surface with a floating layer of polypropylene balls and, where the site requires it, captured under cell covers and hoods held at negative pressure and ducted to a scrubber; close capture is what makes the exhaust volume, and therefore the scrubber and the fan, economically sized, because an open cellhouse under general ventilation has to be diluted with a far larger air volume for the same working result. The second stream is the lean electrolyte, still at 150–180 g/L sulphuric acid with copper reduced by 2–5 g/L. Between 20% and 40% of it is normally returned to the solvent extraction strip stage to carry the acid balance, the remainder is bled to the impurity purge, and a dedicated scavenger cell row takes the residual copper down before the liquor leaves the water balance. Nothing that still carries copper is neutralised to waste. Reagent and utility input: floating polypropylene ball layer, cell covers or hoods with negative-pressure extraction, mist eliminator and scrubber, bleed and scavenger cell row, transfer pumps, acid and copper analysis. Output: captured and scrubbed cellhouse exhaust with the scrubber liquor logged; lean electrolyte returned to solvent extraction, with the bleed polished and the residual copper recovered.

Product Structure (Main Equipment)

The cellhouse is assembled from the five equipment groups below. Materials are selected stream by stream: polymer concrete or vinyl ester resin for cell bodies and integrally cast interiors without a lining joint; 316L austenitic stainless steel for cathode blank blades with copper-clad hanger bars; cold-rolled lead-calcium-tin for anodes; copper or aluminium for busbars according to the current and the cooling arrangement; and PP, PVDF and acid-resistant coatings for hoods, ducting and all wetted parts.

Cells, containment and cellhouse structure

  • Electrowinning cell body. Polymer concrete or vinyl ester resin cell cast as a single piece with an integral interior surface and no lining joint, dimensioned for the cathode count and the liquor volume — a 60-cathode cell of the order of 5.8 m long, 1.2 m wide and 1.4 m deep. Output: the primary reaction vessel, resistant to 150–180 g/L sulphuric acid at 45–50 °C for a service life measured in decades.
  • Cell lining and interior finish. Vinyl ester resin or polymer concrete interior with a smooth, joint-free surface and a defined edge radius, engineered for better than 100 MPa compressive strength and a service life beyond twenty years, and inspected before the electrodes are charged. Output: a cell interior that does not weep, blister or shed into the electrolyte.
  • Electrode support furniture and insulators. Cathode and anode support rails, spacer bars, insulator blocks and cell-top furniture that locate the electrodes at the designed pitch and break stray-current paths to the floor and the structure. Output: repeatable electrode location and suppressed stray current.
  • Cell covers, hoods and close-capture extraction. Cell covers or hoods capable of being held under negative pressure, with the plenum sized to the mist load, delivered with the ducting to the scrubber. Output: acid mist captured at the point of generation instead of diluted across the cellhouse.
  • Access platforms, walkways and aisle steelwork. Walk platforms over the cell rows and access aisle steelwork, which keeps the civil work simple and lets every electrode row be reached for inspection without an improvised arrangement. Output: safe routine access to every cell.
  • Containment bunding and sump. Bunded cell foundations, a lined sump, spill containment and segregated drainage so that electrolyte is recovered rather than lost to the floor. Output: containment of spills and a recoverable liquor return path.
  • Anode straightening and refurbishment station. Anode straightening, cleaning and recoating facilities, because a bowed anode destroys the pitch discipline of an entire cell. Output: anodes returned to service within the straightness tolerance.

Electrodes, current distribution and busbar system

  • 316L stainless steel permanent cathode blank. Austenitic 316L blade with 10–14% nickel and 2–3% molybdenum, roughly 3 mm thick and of the order of 1 m by 1–1.2 m of deposit surface, with a machined 2B finish in the 0.2–0.3 µm Ra range so the copper releases as a full sheet. Output: a long-life deposition surface, rated in well-run tankhouses for up to ten years without repair.
  • Cathode hanger bar and edge strip. Copper-clad hanger bar carrying the current into the blade with the cladding thickness matched to the current, and a moulded edge strip that stops the growing copper from wrapping the blade edges, with second-generation strips lasting beyond four years. Output: low-resistance current entry and a clean, self-releasing cathode edge.
  • Lead-calcium-tin insoluble anode. Cold-rolled Pb-Ca-Sn plate of the order of Pb 99%, Sn 0.8% and Ca 0.04–0.08%, roughly 6 mm thick, cut about 3 cm narrower and shorter than the cathode so edge growth cannot bridge the gap, with a service life of five to ten years. Output: the oxygen-evolving counter-electrode, consumed at 1–12 kg per tonne of copper.
  • Anode hanger bar and contact assembly. Cast or fabricated lead or lead-alloy hanger bar with the contact geometry the busbar design requires. Output: low-resistance anode contact and even current division.
  • Cell voltage monitoring for every cell. Voltage sensing at each cell, brought back to the control system, so that a short circuit or a high-resistance cell is identified by cell rather than by inference from the plant total. Output: a short circuit or a faulted cell located within the shift.
  • Intercell busbar system with equalising bar. Intercell copper or aluminium busbars sized at 1.0–1.2 A/mm² for continuous duty, arranged in a double-contact configuration with an equalising bar on the anode, water-cooled at high current. Output: equal current to every electrode pair with reduced stray current and reduced voltage drop.
  • Electrode contact dressing and thermal inspection set. Contact face dressing tooling, torque-controlled clamps and an infrared thermography set used for the routine contact audit. Output: contacts held below 55 °C, with hotspots found before they cost metal.
  • Lifter beam and electrode handling frames. Crane-suspended lifter beam and frames for lifting cathode and anode sets and cell covers, designed so routine service does not depend on improvisation. Output: safe and repeatable electrode handling.

Power supply, rectification and electrolyte circulation

  • Transformer-rectifier with staged programme. Adjustable, current-limited DC supply with a staged voltage and time programme, built in standard sizes up to tens of kiloamps and specified with the voltage headroom the ramp and the string length require. Output: controlled direct current to the cellhouse string.
  • Rectifier control and protection. Current and voltage regulation, constant-current or constant-voltage mode, parallel-operation controls, alarm interlocks that trip on an abnormal reading, and fail-safe emergency stop. Output: stable current with a defined shutdown behaviour.
  • Circulation pump set with duty and standby. Corrosion-resistant pumps sized to the design circulation rate with one duty and one standby unit, delivering of the order of 0.12 m³/h per square metre of plating area, and arranged so a single cell can be isolated without stopping the string. Output: controlled electrolyte flow and even copper concentration across the electrode gap.
  • Head tank, distribution piping and flow control. Head tank, distribution headers with per-cell balancing valves, and PP or PVDF piping with instrumented flow measurement so that each cell can be verified individually. Output: even flow to every cell, verified rather than assumed.
  • Electrolyte cooling and heating set. Heat exchanger and cooler or cooling tower holding the electrolyte at 45–50 °C, with the duty sized for the rectifier heat load and the site ambient, including at high altitude. Output: a stable temperature window across the diurnal and seasonal range.
  • Filtration and organic knockout. Multimedia or anthracite and garnet filtration plus an organic knockout stage ahead of the cells, because suspended solids and entrained organic are the two fastest routes to cathode roughness and pitting. Output: a particulate-free, organic-free feed to the cellhouse.
  • Reagent dosing station. Metered dosing for chloride at 30–40 mg/L, cobalt at 100–150 mg/L and smoothing agent at 400–500 g per tonne of cathode, with certified pumps and day tanks. Output: deposit quality and anode protection held by measured addition rather than by judgement.
  • Electrolyte analysis bench. Titration apparatus and instrumentation for acid, copper, chloride, cobalt and iron, so the operating window is confirmed by measurement rather than by elapsed time. Output: feed and stage analyses filed against the operating period.

Harvesting, washing and finishing

  • Cathode stripping machine. Full-deposit machine for waxed blanks or bottom edge strips, wax-less V-groove machine producing enveloped or split cathodes, or a robotic machine using one to five robots, sized for the cellhouse peak rate — a 10,000 tonnes per year cellhouse needs of the order of 250 plates per hour, which is about two and a half hours of operation a day. Output: stripped cathode sheets with the blank recovered for immediate return.
  • Cathode washing machine with sequential rinse stages. Multi-stage washing in which the final stage runs on fresh water and the earlier stages on reused water, continuing until the wash water conductivity confirms that entrained electrolyte has been removed. Output: electrolyte-free cathode surface and low-volume wash water retained in circuit.
  • Cathode drying set. Hot air or infrared drying ahead of weighing and bundling, so the sheet does not oxidise in storage. Output: a dry, saleable cathode surface.
  • Weighing, counting and strapping station. Bundle weighing and counting with strapping and marking, producing bundles of declared weight and lot number. Output: strapped bundle with declared weight and identity.
  • Sampling tooling. Punching and drilling tooling selected to avoid iron contamination of the sample, with the sample retained against the bundle number. Output: a representative sample for assay.
  • Cathode shearing or chopping set. Optional downstream sizing where the customer takes cut cathode rather than full sheets, with the offcut returned to the melt. Output: cathode cut to the buyer’s dimension.
  • Blank repair and edge strip station. Blank straightening, surface reconditioning and edge strip replacement equipment, which is what protects the rated ten-year blank life. Output: blanks returned to service within tolerance.
  • Blank return conveyor. Conveyor from the stripping machine back to the cells pitched at three times the electrode pitch, keeping the blank flow one-way and out of the crane aisle. Output: dressed blanks back at the cells without manual handling.

Acid mist control, impurity control and instrument systems

  • Acid mist suppression layer. Floating polypropylene ball layer covering the cell surface, sized to the cell area and arranged in multiple layers where the load requires it. Output: a materially reduced mist emission from the cell surface.
  • Mist eliminator and scrubbing system. Demister and scrubber with the fan and ducting sized to the close-capture exhaust volume, with the scrubber liquor analysed and logged. Output: scrubbed cellhouse exhaust meeting the site emission limit, with a recorded analysis.
  • Impurity bleed and purge control. Instrumented bleed draw-off with the rate set from the chloride, iron and impurity analysis, and the purge routed to the site’s impurity removal step. Output: a controlled impurity inventory in the circulating electrolyte.
  • Scavenger cell row. A dedicated small cellhouse section that takes the residual copper out of the lean electrolyte before it leaves the water balance, arranged at the flow and face velocity the duty requires. Output: residual copper recovered rather than lost to the raffinate or the pond.
  • Acid balance and reagent recovery control. Instrumentation and control for the acid generated at 1.98 g per gram of copper plated, so the surplus is routed to the leach circuit as reagent rather than neutralised. Output: the acid balance closed against the leach plant’s demand.
  • PLC and operator interface with batch logging. Control panel with rectifier control, circulation and temperature loops, cell voltage scanning, alarm annunciation and an event log written against the operating period. Output: reproducible operation and a traceable process record.
  • Emissions and effluent instrumentation. pH, conductivity, flow and metals instrumentation for the scrubber liquor, the bleed and the site effluent, with the analysis filed against the batch record. Output: compliance data produced as a by-product of operation rather than as a separate exercise.

Product Features

  • Current density engineered as a design premise. The electrode area, pitch, circulation rate, busbar section and rectifier rating are all sized for a 250–300 A/m² operating point from the start, so the current density is the basis of the design rather than a derated promise made after the fact.
  • Cell voltage held inside a stated window. The design point is 1.9–2.1 V with a working window of 1.8–2.5 V, and the voltage budget is split into its thermodynamic, anodic, ohmic and hardware components so that a rising voltage is diagnosed by elimination rather than compensated for by raising the setpoint.
  • Permanent cathodes with a genuinely long life. 316L blades at a 0.2–0.3 µm Ra machined finish with copper-clad hanger bars and moulded edge strips, rated for up to ten years without repair in well-run tankhouses against less than three years reported for some alternatives, with the repair station in scope so the rating is maintainable.
  • Anodes deliberately cut back. Pb-Ca-Sn anodes roughly 6 mm thick and about 3 cm narrower and shorter than the cathodes, which is the geometry that stops edge growth from bridging the gap and destroying the cell’s current distribution.
  • Busbar design with an equalising bar and double contact. Intercell bars sized at 1.0–1.2 A/mm² with an equalising bar on the anode, which reduces stray current, reduces the voltage drop, extends anode life and lowers the copper weight required in the busbar itself.
  • Current efficiency treated as the operating result. Cell voltage scanning, contact thermography, nodule knockdown and scheduled cell cleaning are all equipment and routine, not operator discretion, because stray current, short circuits, resistive contacts and iron cycling are the four mechanisms that take efficiency out of the cellhouse.
  • Iron and organic control ahead of the cell. Filtration, organic knockout, a controlled bleed and a scavenger row keep iron below about 3 g/L and keep entrained organic out of the cathode, which is what separates a cellhouse that holds its grade from one that makes inconsistent cathodes.
  • The acid balance designed as part of the plant. For every gram of copper plated, 1.98 g of sulphuric acid is generated; the lean electrolyte leaves at 150–180 g/L and 20–40% of it returns to the solvent extraction strip stage, with the surplus drawn off as leach reagent instead of being neutralised.
  • Acid mist handled by suppression and close capture together. A floating polypropylene ball layer at the cell surface, and cell covers or hoods under negative pressure where the site requires it, so the treated exhaust volume stays small and the scrubber stays economically sized.
  • Chloride and cobalt held as process additives rather than contaminants. Chloride at 30–40 mg/L for deposit smoothness, with the 316L blank specified where chloride exceeds 30 mg/L because above 40 mg/L it starts to pit the blade; cobalt at 100–150 mg/L to suppress lead anode corrosion and hold the lead transfer to the cathode below 1 ppm.
  • Live stripping rather than a stopped tankhouse. Half or one third of a cell’s cathodes are harvested at a time with the remainder still plating, and the blank return conveyor runs at three times the electrode pitch, so the harvest occupies a fraction of the shift.
  • Stripping capacity right-sized to the tonnage. A 10,000 tonnes per year cellhouse is served by a machine of the order of 250 plates per hour running about two and a half hours a day, which is the calculation that decides whether a robotic machine is justified or a conventional one is sufficient.
  • Electrolyte circulation verified cell by cell. Head tank, balancing valves and instrumented flow measurement at 0.12 m³/h per square metre of plating area with a practical ceiling near 0.14, so the flow that makes the current density achievable is confirmed rather than assumed.
  • Wash water kept inside the circuit. Sequential counter-current rinsing with the final stage on fresh water and the earlier stages on reused water, continued to a conductivity endpoint, so both the water and the copper it carries stay in the process.
  • Batch traceability from solution to bundle. Feed assay, electrolyte analysis, cell voltage and current log, cathode weight and count, product assay and the metal balance are held together against the lot number, which is what allows the purity and energy figures to be checked on the customer’s own metal rather than accepted from a specification sheet.

Technical Parameters And Specifications

Parameter Specification
Primary function Electrowinning of dissolved copper from a purified acid sulphate electrolyte onto permanent cathode blanks, producing LME Grade A cathode copper without a dissolvable anode
Process position The metal recovery and finishing stage of a leach, solvent extraction and electrowinning circuit, downstream of solvent extraction and the tankhouse filtration step
Feed solution Copper sulphate in sulphuric acid: solvent extraction strip liquor, leach solution treated by direct electrowinning, spent etching or plating liquor after conditioning, refinery bleed, mine water concentrate or re-dissolved copper sulphate
Cathode current density 250–300 A/m² design band for a solvent-extraction-fed cellhouse; permanent-cathode tankhouses average about 330 A/m² against about 240 A/m² for starter-sheet operations; modern plants operate up to 350–400 A/m², above which the deposit turns rough and nodular; the 2025 world tankhouse survey averages 265 A/m²
Cell voltage 1.8–2.5 V DC per cell as the working window; 1.9–2.1 V at the design point; the budget is about 0.89 V thermodynamic plus the anodic overpotential plus the electrolyte and hardware resistive drop plus stray-current and short-circuit loss
Current efficiency 88–93% design and warranty band; 85–95% is the published industrial range and a well-managed cellhouse holds above 92%
Energy consumption About 1,900–2,000 kWh of DC energy per tonne of cathode copper; approximately 2.2 MWh/t is the published figure for the process as a whole
Electrochemical equivalent 0.02846 kg of copper per ampere-day, which is the basis from which the cell count and the rectifier rating are derived
Cell electrical arrangement Cells hydraulically parallel and electrically in series, so the current is common to the string and the cell voltages add along it
Electrolyte copper — rich 30–50 g/L in the feed to the cell
Electrolyte copper — bite per pass 2–5 g/L removed across a cell; the lean liquor is held above about 30 g/L to avoid sharing the deposition current with hydrogen evolution
Electrolyte acid 150–180 g/L sulphuric acid in the lean electrolyte, held below 170 g/L to limit cathode roughness and mist load
Acid generation 1.98 g of sulphuric acid generated per gram of copper plated, which is the acid that supplies the leach circuit
Electrolyte chloride 30–40 mg/L for deposit smoothness; 316L blanks are specified where chloride exceeds 30 mg/L because above 40 mg/L it starts to pit the blade
Electrolyte cobalt 100–150 mg/L, added to suppress lead anode corrosion and polarisation and to hold lead transfer to the cathode below 1 ppm
Electrolyte iron Tolerated up to about 3 g/L; above that ferric iron cycles back to ferrous at the cathode and gives current away without plating copper
Electrolyte temperature 45–50 °C operating window, held by a heat exchanger and cooler sized for the rectifier heat load and the site ambient, including at high altitude
Smoothing agent 400–500 g per tonne of cathode where the deposit requires it, with the breakdown rate increasing above about 300 A/m²
Circulation 0.12 m³/h per square metre of plating area as the typical good figure, with a practical ceiling near 0.14 m³/h/m², above which spalled anode oxide stays in suspension
Cathode blank material 316L austenitic stainless steel with 10–14% nickel and 2–3% molybdenum as standard; duplex or 304L alternatives where the duty allows
Cathode blank dimensions Of the order of 1 m by 1–1.2 m of deposit surface; blade thickness of roughly 3–3.25 mm; deposit area 2.0–2.04 m² counting both faces
Cathode blank surface finish Machined 2B finish in the 0.2–0.3 µm Ra range, so the copper sheet releases cleanly at stripping
Cathode hanger bar Copper-clad steel bar with the cladding thickness matched to the current, with formed or moulded edge strips at the blade edges
Cathode life Up to ten years without repair in well-run tankhouses for a standard permanent cathode; edge strip replacement interval beyond four years with second-generation moulded strips
Anode material Cold-rolled lead-calcium-tin, of the order of Pb 99%, Sn 0.8% and Ca 0.04–0.08%
Anode dimensions Roughly 6 mm thick, cut about 3 cm narrower and shorter than the cathode so that edge growth cannot bridge the electrode gap
Anode life and consumption Five to ten years of service life, consumed at 1–12 kg per tonne of copper plated, with lead transfer to the cathode held below 1 ppm
Electrode pitch 95–106 mm centre-to-centre as the practical window, 100 mm at the design point, and 99 mm as the 2025 world tankhouse survey average; 95 mm is the practical minimum below which the short-circuit risk is unacceptable
Electrode gap About 45 mm anode-to-cathode, tightening geometrically as the deposit thickens across the cycle
Electrodes per cell Up to about 60 cathodes with 61 anodes in a typical American-style cell, so that every cathode is faced by an anode on both sides
Deposit per cathode Roughly 5 mm thick and 40–60 kg after a 6–8 day cycle, rising to 110–120 kg per cathode in the largest modern operations
Cycle time 6–8 days of plating between harvests, with half or one third of a cell’s cathodes harvested at a time
Cell dimensions Of the order of 5.8 m long, 1.2 m wide and 1.4 m deep for a 60-cathode cell, with the final geometry set by the cathode count and the liquor volume
Cell construction Polymer concrete or vinyl ester resin cast as a single piece with an integral interior surface and no lining joint, better than 100 MPa compressive strength and a service life beyond twenty years
Rectifier Transformer-rectifier built in standard sizes up to tens of kiloamps, with adjustable current and voltage, a staged time programme and the voltage headroom required by the ramp and the string length
Busbar current density 1.0–1.2 A/mm² for continuous duty, with an equalising bar and double contact on the anode and water cooling where the current requires it
Busbar and contact temperature Normal operating contacts below 55 °C; a hotspot above about 150 °C is a resistive joint and is corrected before it costs cathode quality
Monitoring and inspection Per-cell voltage scanning, infrared thermography of contacts and busbar joints, current and voltage logging, temperature, acid, copper, chloride and iron analysis
Stripping Full-deposit machine for waxed blanks or bottom edge strips producing split cathodes, wax-less V-groove machine producing enveloped or split cathodes, or a robotic machine using one to five robots; of the order of 250 plates per hour for a 10,000 tonnes per year cellhouse, and above 600 cathodes per hour achieved on high-capacity lines
Cathode washing Sequential rinse stages with the final stage on fresh water and earlier stages on reused water, continued to a residual conductivity endpoint
Acid mist control Floating polypropylene ball layer at the cell surface, with cell covers or hoods held at negative pressure and ducted to a mist eliminator and scrubber where the site requires close capture
Lean electrolyte handling 20–40% of the lean electrolyte returned to the solvent extraction strip stage, the remainder bled to the impurity purge, with a scavenger cell row recovering the residual copper
Product grade Cathode copper at 99.99% to the Cu-CATH-1 chemistry recognised by LME Grade A, with lead below 5 ppm and sulphur below 15 ppm; the standard cross-walk is LME Grade A, BS EN 1978 Cu-CATH-1, ASTM B115 Grade 1 and GB/T 467-2010
Product form Full-sheet cathode, strapped bundles of declared weight, or cut cathode where the buyer specifies a dimension
Materials of construction — wetted parts Polymer concrete, vinyl ester resin, 316L stainless steel, PP and PVDF, with coatings matched to acid mist service; 316L specified for blanks where chloride exceeds 30 mg/L
Instrumentation and control PLC with operator interface, rectifier control with staged programme, circulation and temperature loops, per-cell voltage scanning, alarm annunciation, emergency stop and an event log written against the operating period
Utilities and consumables Electrical power at the rectifier rating, cooling water or air, wash water, chloride, cobalt and smoothing agent, filter media, edge strips and lead anodes on their scheduled interval
Capacity, cell count, electrode area, power, footprint and utilities Engineered to your feed assay, monthly copper volume, target cathode grade and site conditions
Installation Indoor cellhouse on a level bunded floor, with the crane, containment, drainage and ventilation arrangements shown on the layout drawing

Technical Advantages

  • The design window is published, so it can be checked. 250–300 A/m², 1.8–2.5 V, 88–93% current efficiency and 1,900–2,000 kWh per tonne are stated as the basis of the hardware, against an industry norm in which supplier pages describe capability and publish no operating parameters at all. A buyer can therefore test the sizing arithmetic against their own copper balance before committing capital.
  • The cell count is derived, not asserted. With 0.02846 kg of copper per ampere-day, a deposit area of 2.0–2.04 m² per cathode and the design current density, the cell count follows from the target tonnage and the time efficiency. The working is supplied with the quotation, which is what makes the sizing auditable rather than a matter of trust.
  • The voltage budget is managed in its parts. Only the 0.89 V of thermodynamic potential is fixed. Anodic overpotential is addressed by anode composition and cobalt addition, the ohmic term by the 95–106 mm pitch and the 45 mm gap, and the hardware and stray-current term by machining contacts, insulated supports and equalising-bar double contact. Treating the total as a setpoint instead of a budget is what leaves competing cells at 2.5 V and above.
  • Current efficiency is defended by equipment and routine. Cell voltage scanning, contact thermography, nodule knockdown and scheduled cleaning address stray current, short circuits, resistive contacts and iron cycling in turn. The documented gain from hotspot control alone — 5.4% current efficiency, equivalent to about 74 tonnes of Grade A cathode in six weeks — is larger than the difference between a cheap rectifier and a good one.
  • Permanent cathodes remove an entire process loop. No starter-sheet plating, no starter-sheet stripping and no starter-sheet scrap, which is why permanent cathodes now stand in about 80% of tankhouses and carry roughly 94% of hydrometallurgical cathode production. The blank is a ten-year asset rather than a consumable, and the repair station in scope is what keeps that rating honest.
  • Anode geometry prevents the failure it is designed around. Cutting the anode about 3 cm narrower and shorter than the cathode is a deliberate decision to reject edge growth, which is the mechanism by which a cathode bridges to its neighbour, destroys the current distribution in the cell and forces an unplanned shutdown.
  • Busbar design reduces four costs at once. The equalising bar and double-contact arrangement lowers stray current, extends anode life, improves cathode quality and reduces the copper weight the busbar needs — and busbar copper is one of the largest single material costs in a cellhouse.
  • Iron and organics are controlled rather than tolerated. Filtration, organic knockout, a measured bleed and a scavenger row hold iron below about 3 g/L, because ferric iron shuttled back to ferrous at the cathode is current spent without copper produced, and hold entrained organic out of the deposit, because organic inclusions cannot be removed by washing.
  • The acid balance is an asset rather than a disposal problem. The 1.98 g of acid generated per gram of copper plated is returned to the leach circuit as reagent, with 20–40% of the lean electrolyte routed back to solvent extraction. An electrowinning plant that neutralises its acid is paying twice: once for the neutralising reagent and once for the acid it then has to buy.
  • Acid mist is answered at the cell. Suppression at the surface plus close capture under negative pressure keeps the treated exhaust volume small, which is the difference between a compact scrubber and a very large one, and it addresses the exposure at the point where the oxygen evolution actually occurs.
  • Harvest capacity is matched to tonnage rather than maximised. A machine rated for the cellhouse’s real peak output is cheaper and more reliable than the largest machine available; at 10,000 tonnes per year, 250 plates per hour occupies about two and a half hours of the day, which leaves the crane and the labour available for the rest of the shift.
  • The product is finished to a deliverable, not to a plate. Sequential counter-current washing, conductivity-endpoint control, controlled sampling and strapped bundles of declared weight are what allow the cathode to be shipped against its assay instead of re-melted, and that is where the final margin on the tonnage is actually realised.
  • Configuration stated in writing before manufacture. The cell count, cathode area, electrode pitch, rectifier rating, busbar section, circulation rate, cooling duty, exhaust volume and scavenger capacity are engineered from your solution assay and monthly copper volume, and the resulting figures are set out in the process design package rather than left to be discovered at commissioning.

Service Process

Step 1 — Feed Characterisation and Consultation. Send a representative sample of your solution or the analysis from your own laboratory, together with the feed source, the monthly copper volume you intend to produce, the target cathode grade and the site conditions. Our metallurgical team assays the rich and lean streams for copper, free acid, chloride, cobalt, iron, manganese, nickel, antimony, bismuth and arsenic, determines suspended solids and entrained organic, and identifies the constraints the assay places on the route — chloride above 40 mg/L on the blank material, iron above about 3 g/L on the bleed rate, organic carry-over on the filtration and knockout duty. Output: assay report and a preliminary cellhouse concept with the achievable current density, cathode grade and acid balance.

Step 2 — Laboratory and Pilot Test Work. Bench and pilot electrowinning campaigns confirm the design current density on your own liquor, the deposit morphology and stripping behaviour that current density produces, the current efficiency the impurity load allows, the additive dosages for chloride, cobalt and smoothing agent, and the bleed rate needed to hold the impurity inventory. Where solvent extraction or filtration sits upstream and is not yet fixed, the test work establishes what those stages have to deliver for the cellhouse to reach its design point. Output: test report with the confirmed current density, current efficiency, additive schedule and bleed rate.

Step 3 — Process Design and Quotation. The results are converted into a copper, acid and water balance, a flowsheet, a cellhouse sizing calculation, the cell and electrode geometry, the rectifier rating, the busbar section, the circulation and cooling duty, the exhaust and scrubber duty, the scavenger cell capacity, a layout and a utility schedule against your throughput and site. The cell count is derived from the target tonnage, the deposit area per cathode, the current density, the current efficiency and the time efficiency, and the working is shown. Output: process design package and firm quotation with the sizing arithmetic attached.

Step 4 — Detailed Engineering and Manufacturing. Cell bodies and interiors, electrode support furniture and insulators, cathode blanks with hanger bars and edge strips, lead anodes, the intercell busbar system with equalising bar, the transformer-rectifier, circulation pumps, head tank and piping, the cooling set, filtration and organic knockout, reagent dosing, cell covers and ducting, the mist eliminator and scrubber, the stripping machine, the washing and drying set, the weighing, strapping and sampling stations, the blank return conveyor and the control system are fabricated, pre-assembled and piped. Output: engineered, pre-assembled equipment modules.

Step 5 — Factory Assembly, Testing and Acceptance. Each module is functionally tested, and the rectifier, the control system, the stripping machine and the circulation set are trial-run with the client invited to attend the factory acceptance test before shipment. Output: FAT-approved, pre-commissioned modules.

Step 6 — Shipping, Installation and Commissioning. We supervise the civil interface, cell setting and alignment, busbar installation, piping, ducting, crane and machine erection and electrical tie-in, then run an instrumented commissioning campaign on your electrolyte until the contracted cathode grade, current density, current efficiency and energy per tonne are demonstrated and the cellhouse exhaust is verified against your local emission limit. Output: a producing cellhouse at contracted performance.

Step 7 — Operator Training, Handover and Ongoing Support. On-site training covers electrolyte handling and analysis, blank dressing and electrode pitch discipline, cell charging and the current ramp, cell voltage scanning and contact thermography, nodule knockdown and cell cleaning, the harvest and stripping routine, washing and sampling, acid mist and scrubber operation, bleed and scavenger control, and emergency procedures, supported by standard operating procedures and a full handover dossier. Ongoing support adds remote troubleshooting, spares and consumables, blank and edge strip service, anode replacement scheduling, and periodic performance audits in which the cathode assay, the current efficiency and the energy per tonne are reviewed against the design. Output: trained crew, complete documentation and sustained performance across the life of the plant.

Warranty And After-Sales Service

  • Warranty period. Twelve months from commissioning or eighteen months from shipment, whichever falls first, covering design, materials and workmanship of the equipment supplied, with the terms and the excluded wear parts stated in the contract.
  • Performance undertaking. The current density, current efficiency, cathode grade and energy per tonne stated in the process design package are demonstrated during commissioning on your own electrolyte, and the acceptance test conditions and tolerances are agreed in the contract rather than left to interpretation. Output: a documented performance test against the design figures.
  • Wear part and consumable clarity. Lead anodes, edge strips, filter media, gaskets, pump seals, scrubber packing and mist suppression balls are identified as consumables with their expected service intervals declared up front, so the operating cost of the cellhouse is visible before it is commissioned rather than after. Output: a declared consumable schedule and cost basis.
  • Spare parts availability. A recommended commissioning and first-year spares set is quoted with the cellhouse, and spares remain available through the equipment’s service life with lead times stated at order. Output: continuity of supply against a declared list.
  • Remote support. Telephone, email and messaging support for operating questions, alarm interpretation, cathode quality problems, current efficiency deviations, cell voltage anomalies and stripping faults while your plant is running. Output: same-day response on operating issues.
  • On-site service. Engineer attendance for warranty faults, process problems and periodic check-ups, with response and attendance times agreed in the contract according to your location. Output: on-site intervention and a service report.
  • Blank and edge strip service. Inspection, straightening, surface reconditioning and edge strip replacement for the permanent cathode set, with a documented condition assessment at each interval, because the rated blank life depends on that maintenance being done. Output: blanks maintained within the tolerance that supports their rated life.
  • Anode campaign management. Support for lead anode straightening, cleaning, recoating and replacement scheduling, and for the cobalt and chloride control that governs anode life and lead transfer to the cathode. Output: an anode replacement plan and a measured lead-in-cathode figure.
  • Assay and metal balance verification service. Periodic verification of the cathode assay, the electrolyte analysis and the current efficiency and energy figures against your own laboratory results, so the performance of the cellhouse is tracked over time rather than assumed from commissioning. Output: verification report against the operating records.
  • Operator retraining and refresher visits. Additional training, refresher sessions and process optimisation visits as your feed source, impurity load or product requirement changes. Output: updated training and revised procedures.
  • Documentation set. Operation and maintenance manuals, process flow diagram, cell and electrode drawings, busbar and electrical drawings, control philosophy, layout, spare parts catalogue, safety data for sulphuric acid, the reagents used and lead-bearing materials, and the emergency response plan covering acid exposure, electrolyte spillage and electrical isolation. Output: complete documentation handover.
  • Compliance support. Assistance with emission and effluent parameter declarations, scrubber performance verification, and the handling, storage and disposal requirements for acid-bearing process liquors and for the lead-bearing anodes and any residual materials generated in the line. Output: technical data for your permit applications.
  • Lifetime technical support. The process design remains yours, and our engineering team remains available for modification, debottlenecking and expansion advice for the operating life of the cellhouse. Output: long-term engineering continuity.

Frequently Asked Questions

What is copper electrowinning equipment used for?

Copper electrowinning equipment recovers copper from a solution by passing direct current through a purified copper sulphate electrolyte and reducing the cupric ion onto a cathode blank as metallic copper. It is the final stage of a leach, solvent extraction and electrowinning circuit, and it is the route to cathode metal for feed that no smelter will take: oxide and mixed ore leach solutions, tailings and stockpile leachate, mine water, secondary copper and electronic scrap leach liquors, spent etching and plating solutions, and refinery bleed streams. A cellhouse sits downstream of solvent extraction, which lifts the copper into a clean high-acid strip liquor and rejects iron, manganese and chloride to the raffinate, and its output is a full sheet of cathode copper at 99.99% that is shipped and sold as metal rather than as a concentrate.

What cathode purity does copper electrowinning achieve?

Cathode copper at 99.99%, meeting the Cu-CATH-1 chemical composition that LME Grade A recognises, with lead held below 5 ppm and sulphur below 15 ppm. The same grade is described by BS EN 1978 as Cu-CATH-1, by ASTM B115 as Grade 1 and by GB/T 467 as high-purity copper cathode, and the four designations are used interchangeably in the market for the same deliverable chemistry. What makes the grade achievable is not the cell itself but the discipline around it: solvent extraction upstream to strip the impurities, chloride and cobalt held inside their windows, iron below about 3 g/L, no entrained organic reaching the cathode, close contact temperature control at the electrodes, and a wash that removes entrained electrolyte before the sheet is bundled. Purity is verified on the customer’s own metal, by sampling and assay per lot, rather than accepted from a specification sheet.

What is the difference between copper electrowinning and copper electrorefining?

The anode. In electrorefining the anode is impure copper metal that dissolves as the cell operates, so the copper comes from the anode, anode scrap and anode slime are part of the flowsheet, and the cell runs at only about 0.25–0.3 V because the dissolution potential offsets most of the deposition cost. In electrowinning the anode is insoluble — a lead-calcium-tin plate that never dissolves — and the copper comes entirely from the solution, with oxygen rather than copper evolved at the anode. That is why an electrowinning cell runs at 1.8–2.5 V and consumes roughly ten times the electrical energy per tonne, and it is also why electrowinning can accept a dilute and relatively dirty leach liquor that an electrorefining line could not touch, and why it generates no anode scrap and no meaningful anode slime to be re-melted. If your feedstock is metallic copper, you need electrorefining; if your feedstock is a solution, electrowinning is the only route to cathode metal without a smelter.

What cathode current density does the cellhouse run at, and why is it capped?

The design band for a cellhouse fed by solvent extraction and filtration is 250–300 A/m² of cathode area. Permanent-cathode tankhouses average about 330 A/m² against about 240 A/m² for starter-sheet operations, modern plants operate up to 350–400 A/m², and the 2025 world tankhouse survey averages 265 A/m² across all plants. The cap exists because current density is limited by the rate at which copper ions can be delivered to the cathode surface, not by the rectifier. Push past that rate and the surplus current is consumed by hydrogen evolution instead, the deposit grows nodular and dendritic, nodules bridge the electrode gap and short-circuit the cell, and current efficiency falls away faster than the tonnage rises. One documented case is instructive: a plant designed for 275 A/m² on purified feed achieved only about 75–110 A/m² on un-purified leach solution before the deposit became unmanageable, which is the practical reason filtration and solvent extraction are treated as part of the cellhouse design rather than as upstream conveniences.

What is the cell voltage made up of, and why does it matter more than the current?

The cell voltage is a budget of four terms: about 0.89 V of thermodynamic potential that the chemistry fixes, the anodic overpotential needed to evolve oxygen on a lead alloy surface, the resistive drop across the electrolyte gap and the cell hardware, and the loss to stray currents and short circuits. Only the first term is immovable. The other three are design variables — the anodic term is addressed by anode composition and cobalt addition, the ohmic term by the 95–106 mm electrode pitch and the 45 mm anode-to-cathode gap, and the hardware term by machined contacts, correct busbar section and insulated supports. A cell running at 1.9–2.1 V is converting almost all of its electrical input into copper; a cell running above 2.5 V is buying water decomposition with the same current, which shows up directly in the energy per tonne and in the roughness of the deposit.

What electrolyte composition does the cellhouse run, and why is the acid held below 170 g/L?

Copper is held at 30–50 g/L in the rich electrolyte with the cell allowed to bite 2–5 g/L out of it per pass, and the lean liquor is kept above about 30 g/L because below that figure hydrogen evolution begins to share the deposition current and cathode quality falls away. Sulphuric acid runs at 150–180 g/L, and the lean stream is deliberately held below 170 g/L. Acid is not a free variable: it is what drives acid mist generation at the cell surface, and it affects the deposit roughness and the solubility balance. Because the cell generates 1.98 g of sulphuric acid for every gram of copper plated, the acid concentration rises as the cell works, and holding it below the ceiling is an operating constraint as much as a design one. Temperature runs at 45–50 °C, which lowers the electrolyte resistance and improves ion mobility without driving evaporation and mist losses up.

Why is chloride added to the electrolyte rather than removed?

Chloride at 30–40 mg/L is a deliberate additive, not a contaminant. It acts as a deposit-smoothing agent at the cathode, producing a dense coherent sheet that releases cleanly at stripping instead of a rough one that tears. It does interact with the hardware, which is why the material selection responds to it: above about 40 mg/L, chloride begins to pit 316L stainless steel blanks, and South American tankhouses handling more than 30 mg/L of chloride all run 316L rather than a cheaper grade. The chloride window is therefore narrow in both directions — too little and the deposit is rough, too much and the blank is attacked — and it is controlled by measured addition and periodic titration rather than by trusting the feed analysis.

What does cobalt do in a copper electrowinning cell?

Cobalt is held at 100–150 mg/L to protect the lead anodes. Lead-calcium-tin anodes corrode and polarise in sulphuric acid service as the oxide film on their surface forms and breaks down, and cobalt in the electrolyte stabilises that film, which suppresses both the corrosion rate and the anodic overpotential. The benefit shows up twice: the anodes last longer, moving towards the upper end of their five-to-ten-year service life and holding their consumption towards the lower end of the 1–12 kg per tonne range, and the cell voltage stays lower because a stable oxide film is a lower-resistance surface. Cobalt also reduces the amount of lead that reports to the cathode, which is what keeps the lead figure in the cathode assay below 5 ppm and keeps the product inside the Grade A composition.

Why are permanent cathodes used instead of starter sheets?

Because a starter sheet is a second plating operation. A conventional starter-sheet tankhouse has to plate a thin copper sheet on a titanium or stainless mother blank, strip it, hang it as a cathode, harvest the copper that grows on it, and then deal with the starter sheet itself. Permanent cathodes remove that loop entirely: a 316L blank is dressed, charged, plated and stripped, and it returns directly to the cell. The consequences are visible in the industry data — permanent cathodes now stand in about 80% of tankhouses and carry roughly 94% of hydrometallurgical cathode production, with starter-sheet plants concentrated among installations built in the twentieth century. The trade-off is capital: a permanent cathode set is a significant material cost, but it is a long-lived asset rather than a consumable, and its rated life depends on the blank repair and edge strip discipline being maintained.

How thick is a 316L cathode blank, and how long does it last?

A standard permanent cathode blade is 316L austenitic stainless steel, containing 10–14% nickel and 2–3% molybdenum, at roughly 3–3.25 mm thick and of the order of 1 m by 1–1.2 m of deposit surface, giving 2.0–2.04 m² of plating area counting both faces. The surface finish matters as much as the thickness: a machined 2B finish in the 0.2–0.3 µm Ra range is what allows the copper sheet to release cleanly without tearing the edges. On life, the practical figures are wide, which is why the design details matter — standard permanent cathodes are rated for up to ten years without repair in well-run tankhouses, against less than three years reported for some alternative designs, and the copper-clad hanger bar, its cladding thickness and the moulded edge strips are the components that decide which end of that range a plant reaches. Relying on a cheap blade to save capital is the single most common way to increase the real cost of a cellhouse.

Why is the anode cut narrower and shorter than the cathode?

To reject edge growth. Copper does not plate only on the flat faces of the blank: it also grows around the edges and the bottom, and if the anode extends as far as the cathode, that growth is deposited at a very high local current density because the geometry concentrates the field there. The result is a thick, rough, dendritic bead along the cathode edge that eventually reaches the neighbouring cathode across the busbar gap and short-circuits the cell. Cutting the anode roughly 3 cm narrower and shorter than the cathode is a cheap geometric decision that removes the driver for that growth, and it complements the moulded edge strip on the blank. It is also why anode straightness is enforced: a bowed anode has the same effect as an anode that is too large, because part of its face ends up closer than the design gap.

How is the cathode harvested without stopping the tankhouse?

The harvest is a scheduled operation inside a continuing shift rather than a shutdown. Half or one third of a cell’s cathodes are pulled at a time — which is why practical cathode counts are divisible by two or three — and the remaining electrodes continue to plate while the crane works its way along the cell row. The loaded blanks go to the stripping machine, the copper sheet is separated from the blank, the blank is inspected and returned to the cells on a conveyor pitched at three times the electrode pitch, and the sheet goes forward to washing, drying, weighing and bundling. The stripping machine is sized to the cellhouse’s real peak rate rather than to the largest available: for a 10,000 tonnes per year cellhouse a machine rated around 250 plates per hour occupies about two and a half hours of the day, while continuous machines above 600 cathodes per hour exist for very large electrorefining tankhouses where the daily cathode count is far higher.

How is the number of cells and the rectifier rating calculated for a target tonnage?

The calculation starts from the electrochemical equivalent of copper, 0.02846 kg per ampere-day. Take the target annual tonnage, divide by the yearly operating days to get daily output, and the daily copper per cell follows from the deposit area of one cathode, the cathode count in the cell, the design current density, the current efficiency and the time efficiency. From that, the cell count is the daily target divided by the daily output of one cell, rounded up to a practical arrangement, and the rectifier is sized at the maximum current the cellhouse can draw — deposit area per cathode, times cathodes per cell, times the number of cells, times the highest current density the plant will ever run — with the voltage set from the design cell voltage multiplied by the number of cells in the string. The rectifier is then specified at the next standard size above that maximum, which is why the published rating of a cellhouse rectifier is always slightly higher than the calculated duty. YuSai supplies this arithmetic with the quotation so the buyer can check it against their own balance.

Where does the acid generated in the cell go, and why does it matter to the leach plant?

Every gram of copper plated generates 1.98 g of sulphuric acid, and the cellhouse is the largest single acid source in a hydrometallurgical copper circuit. That acid is not a waste product; it is the leach reagent. In a heap leach operation the lean electrolyte leaving the cellhouse at 150–180 g/L sulphuric acid is returned to the solvent extraction strip stage, and between 20% and 40% of the lean flow goes back there to carry the acid balance, with the remainder bled to the impurity purge. The plant’s entire acid balance therefore depends on how much copper the cellhouse plates, and the consequence for design is that a cellhouse cannot be sized in isolation: the acid it generates, the acid the leach consumes and the acid the raffinate carries are one coupled system, and the whole mass balance is built as a single calculation.

How is acid mist controlled in the cellhouse?

Acid mist is generated at the anode, where oxygen evolution breaks the electrolyte surface and carries sulphuric acid into the atmosphere as a fine aerosol. The response is suppression plus capture. At the cell surface, a floating layer of polypropylene balls covers the electrolyte and knocks down the mist mechanically; where the site requires close control, cell covers or hoods are held at negative pressure and the headspace is ducted through a mist eliminator to a scrubber. Close capture is what makes the system economical, because an open cellhouse under general ventilation has to be diluted with a far larger air volume to reach the same working atmosphere, and the scrubber and fan have to be sized for that diluted volume. The scrubber liquor is analysed and logged, so the emission record is produced as a by-product of operating the plant rather than as a separate compliance exercise.

Can copper electrowinning treat a leach solution without solvent extraction?

It can, and the design changes in a predictable way. Direct electrowinning of an un-purified leach solution is feasible, but the iron, manganese, aluminium and chloride that solvent extraction would have rejected all remain in the cell feed, and the deposit tolerates a much lower current density as a result. The documented experience is that a cellhouse designed for about 275 A/m² on purified feed achieved only roughly 75–110 A/m² on a raw pregnant leach solution before the deposit became unacceptable. The practical consequence is that direct electrowinning works best on a clean or a high-tenor liquor, such as spent etching solution or a well-conditioned leachate, and that where solution purification is not used the cellhouse has to be sized with a materially larger electrode area, and therefore a larger capital cost, to reach the same tonnage. That comparison is what normally decides the question, and it is settled in the test campaign rather than on the drawing board.

What capacity can you supply, and how is the cellhouse configured?

Capacity is engineered to your solution assay and your monthly copper volume rather than taken from a catalogue of fixed models. What matters is the copper tenor of the feed, the impurity load that sets the achievable current density, the target cathode grade, and the electrode area needed to carry the target current at that current density — so two cellhouses quoted at the same daily copper output can require rather different cell counts and rectifier ratings depending on what is in the solution. YuSai sizes the cell count, the cathode area, the electrode pitch, the rectifier rating, the busbar section, the circulation rate, the cooling duty, the exhaust and scrubber duty and the scavenger capacity from your analysis and your target copper volume, and states the resulting figures in the process design package. The cellhouse is laid out modularly, so a line that proves the route at a modest tonnage can be extended by adding cells and rectifier capacity in parallel rather than by being replaced.

Get A Free Quote

Fill in the form below and our service team will get back to you within 24 hours with a recommended process flow and quotation.

If you be interested in our equipment and solutions, please to contact us.

Get a free quote

Please leave your contact information, and our technicians will reply to you within 2 hours.Thanks!